Balance King
Power your dream
6
Balance King 6000
Output
+3.3
V
+5
V
+12
V1
+12
V2
+12
V3
+12
V4
-12
V
+5
VSB
Max.
Load
24.0A 24.0A 16.0A 16.0A 16.0A 16.0A 0.5A 3.0A
Min.
Load
1.5A 1.0A 0.8A 0.8A 1.0A 0.5A 0.0A 0.1A
Rated Power: 600W
Maximum continuous combined load on +3.3V and +5V outputs shall not
exceed 140W.
Maximum combined current for the +12V1, +12V2, +12V3 and +12V4 is
48A.
2.2 Output Ripple & Noise
+3.3V +5V +12V1,2,3,4 -12V +5VSB
Ripple
&Noise
50
mVp-p
50
mVp-p
120
mVp-p
120
mVp-p
50
mVp-p
2.3 Output protection
If the power supply is latch into shutdown stage (when OCP ,OVP or
short protection is working ),the power supply shall return to normal
operation only after the fault has been removed and remote signal must
reset for a minimum of 1 second (or the AC removed for 10 second) . Then,
it will turn on again.
2.3.1 Over Voltage Protection (OVP)
In case of over voltage limits are exceeded, the power supply shall
provide latch-mode over-voltage protection.